BRT(Bus Rapid Transit) & Tram Rail Transit Platform Screen Door

SEND INQUIRY NOW

Art. Nr. 1077.PSD01

Platform Screen Door (PSD) is a safety barrier installed at the edge of a railway or subway platform to prevent passengers from falling onto the tracks. It enhances safety, improves ventilation control, and increases energy efficiency in underground stations.


SEND INQUIRY NOW
  • 1077.PSD01 Platform Screen Door.pdf Download
Send your inquiry

Types of Platform Screen Doors:

1. Full-Height (Closed-Type) PSDs 

● Extend from the floor to the ceiling.  

● Fully enclosed, similar to elevator doors.  

● Common in automated metro systems (e.g., Singapore MRT, Dubai Metro).  


2. Half-Height (Open-Type) PSDs  

● Usually around 1.5-1.7m meters tall.  

● Prevents falls but allows airflow (e.g., Tokyo Metro, some London Underground stations).  


3. Automatic Platform Gates 

● Minimalist barriers (waist-high) with sliding doors.  

● Used in some commuter rail systems (e.g., parts of Beijing Subway). 


Advantages

● Safety – Prevents accidents, suicides, and unauthorized track access.  

● Energy Efficiency– Reduces air conditioning loss in climate-controlled stations.  

● Dust & Noise Control– Blocks track debris and reduces noise from trains.  

● Security – Helps deter crime and terrorism by restricting access.  


Technical Specifications

1. PSD Platform screen door system

The PSD door system consists of shielded safety doors, a power distribution system, and a management monitoring system. The PSD is the final execution device to realize the system function, including: drive system, control system, etc. The PSD transformer device (DC24V) is designed and installed in conjunction with equipment such as high-voltage control and UPS backup power.


2. Main principles of settings

● The layout of the PSD door should correspond to the location of the sidewalk.

● The layout of the PSD door at the station must meet the requirements of limitation. The center of the PSD door and the center line of the railing should be basically the same, and in any case can not exceed the edge of the platform.

● The PSD door system must have a fast-enough door opening and closing speed, and the working intensity should at least meet the interval requirements of traffic lights at intersections.

● The PSD door should have an obstacle detection function. During the opening and closing of the PSD door, effective measures should be taken to prevent the passenger from being pinched.

● The PSD door body should have sufficient strength and rigidity. Even under the most unfavorable combination of load conditions, the deformation of each part of the door body perpendicular to the direction of the roadway shall not exceed ±15mm.

● The structure design and material selection of PSD door meet the requirements of open-air working environment. Considering changes in temperature and humidity, as well as damage from rain and snow, it should be resistant to 

mildew and corrosion.

● PSD doors should be easy to install, adjust, disassemble, and repair, with less working load.

● Stainless steel or aluminum materials shall be selected for the frame and panel of the PSD door body to meet the requirements of Class A non-flammability. Effective measures should be taken to prevent passengers from being pinched during operation. For those cannot use non-flammable materials, such as wires, cables and sealing materials, they should be flame retardant, low smoke, halogen-free, and nonradioactive.

● PSD door system should adopt products that has the following advantages: advanced technology, reliable performance, reasonable structure, stable quality, safe and reliable operation, easy to disassemble, debug and maintain, beautiful appearance.


               
               

Main technical parameters of platform PSD door


(1). Quantity of PSD doors8 doors, one set of control system.
(2). Total length of each door unit4000mm.
(3). Opening modesingle opening mode
(4). Net opening width1500 mm (+5%).
(5). Total height of PSD door1200mm.
(6). Total thickness of PSD door≦210mm.
(7). Closing force of each PSD door≤150N (measured when the door is closed to one-third of the stroke)
(8). Manual opening force when PSD door is unlocked≤ 133N.
(9). The maximum kinetic energy of each PSD door should be≤10J.
(10). PSD door opening time2.5±0.1s~3.5±0.1s adjustable within range (adjust according to time interval of traffic lights).
(11). PSD door closing time3.2±0.1s~4.0±0.1s adjustable within the range (adjust according to vehicle parameters).
(12). PSD door reaction time≤0.3s (adjustable).
(13). Noise level (platform side)<70dB (A).
(14). Overall service life of the system≥ 8 years (under normal maintenance conditions).
(15). Average number of times of trouble-free use should be≥1 million times.
(16). Power supplyDC 24V (12V).
(17). Load condition①. Passenger crushing load1500N/m anti-load (1.1m from the platform decoration surface, no permanent deformation of the structure).
②. Passenger impact1500N (1.125m height, working area 100×100mm, in 0.2S time, no permanent deformation of the structure).
③. Wind LoadConsider the wind pressure of Class 7 Typhoon 1000N/m2.
               
               
               
Technical Requirements for Major Components

The PSD door system consists of two parts, mechanical and electrical. The mechanical part includes a door structure and a door drive system; the electrical part includes a power supply system and a control system.


               
               
               

               


Phone:
+86 13958170284
Telephone:
86-571-88177797
Add a comment
IF YOU HAVE MORE QUESTIONS,WRITE TO US
Just tell us your requirements, we can do more than you can imagine.
Choose a different language
╳
English
العربية
Latin
Türkçe
Suomi
русский
Português
français
Español
Current language:English

Send your inquiry